SLM-MD Air Spring Isolator

SLM-MD Air Spring Isolator - vibration isolation solution

Structure:

Elastomer-metal combination with screwable
base plate, gas chamber made of elastomeric
material, reinforced with steel rings, 10 sizes.

Performance:

• Low-frequency active or passive damping
• The vertical and horizontal stiffness is
about 1:1
• Vibration isolation
• Impact absorption
• Structural soundproofing
• No anchoring is required
• It can be operated without inflation
• Load range: 0.2 – 100 kN
• Natural frequency (static) 3 – 5 Hz
• Natural frequency (static) is not inflated at 8Hz

Leveling Range:
±5 - 6 mm, barometric control
 
Options:
Automatic leveling control:
• Mechanical-pneumatic version
• Electric-pneumatic version
 
SLM seriesDiameterInstallation height H0Base size D1The support surface fixes the size of the threaded hole GOverall length LMachine foot thickness(max.)Lifting range of height NiHeight of support surface XWidth of base plate ABase hole spacing bBase fixing hole size dBase plate thicknessWeight
kg
Maximum load
kN
SLM 1 73 65 28 M10 80 50 ±5 12 75 60 7 3 0.3 0.65
SLM 3 105 65 52 M12 90 65 ±5 12 105 89 7 3 0.5 1.8
SLM 6 127 90 60 M12 90 65 ±6 15 130 108 7 3 1.0 2.8
SLM 12 172 90 96 M12 90 65 ±6 15 175 153 7 3 2.2 6.0
SLM 24 245 90 138 M16 100 75 ±6 15 255 215 14 5 7.2 13.0
SLM 48 338 90 205 M16 100 75 ±6 15 343 305 14 5 14.7 26.0
SLM 72 380 91 255 M24 x 1.5 140 75 ±6 17 385 310 20 6 22.5 38.0
SLM 96 468 90 300 M24 130 75 ±6 15 470 406 20 6 29.3 55.0
SLM 144 550 91 360 M24 x 1.5 140 75 ±6 17 555 480 20 6 46.5 76.0
SLM 192 610 90 430 M24 130 75 ±6 15 610 508 20 6 52.5 100.0
 

Unit: mm