FLEX-LOC
APPLICATIONS
FLEX-LOC are suitable for the fixing of sheets, frameworks, engines, ventilators, electronic equipment, computers, etc.
They have, moreover, a function of insulation against the structure borne noises, unlike other fasteners
Advantages
80% reduction at 150 Hz of vibrational energy transmitted from normal structural frequencies.
➤Simple and economical.
➤ Simple to fix.
➤ Light weight.
OPERATION
The design of the FLEX-LOC mount gives the following basic characteristics :
➤ the rubber works in :
- compression (axial);
- shear (radial);
➤compression/shear according to the fixing method.
DIMENSIONS



|
Paulstra reference |
Barry Controls* reference |
Nut |
cp A (mm) |
cp B (mm) |
C (mm) |
D (mm) |
E (mm) |
F (mm) |
| 530909 03 | Q3 | M3 | 9 | 7,2 | 3,4 | 9 | 2,5 | 8 |
| 530909 04 | Q4 | M4 | 12 | 9,3 | 4,4 | 11,5 | 3 | 10,5 |
| 530909 05 | Q5 | M5 | 15 | 10,2 | 5,4 | 14,5 | 3,5 | 13 |
| 530909 06 | Q6 | M6 | 18 | 12,7 | 6,4 | 17 | 4 | 15 |
| 530909 07 | Q8 | M8 | 24 | 16,5 | 8,4 | 22 | 5 | 19,5 |

|
Paulstra reference |
Barry Controls* reference |
Clearance
hole Ø B(mm) |
Plate
thickness G(mm) |
Torque range | Static load (daN) (daN) | |||
|
1 (Nm) |
2 or 3 (Nm) |
1 | 2 or 3 | |||||
|
Compression
/ shear
|
Compression | Shear | ||||||
| 530909 03 | Q3 | 7,2-7,5 | 0,6-2,5 | 0,5 | 0,4 | 1 | 5 | 2,5 |
| 530909 04 | Q4 | 9,3-9,6 | 0,8-3,3 | 0,6 | 0,5 | 1 | 7 | 3,5 |
| 530909 05 | Q5 | 10,2-10,5 | 0,8-4,3 | 1,0 | 0,6 | 1,5 | 10 | 5 |
| 530909 06 | Q6 | 12,7-13,0 | 1,5-5,0 | 3,5 | 0,9 | 3 | 14 | 7 |
| 530909 07 | Q8 | 16,5-16,8 | 1,5-6,5 | 4,0 | 1,8 | 5 | 28 | 14 |