SLM-A/B Air Spring Isolator
Structure:
Elastomer-metal combination with screwable
base plate, gas chamber made of elastomeric
material, reinforced with steel rings, 10 sizes.
Applicable Fields:
Measuring machines, flat workbenches,
equipment foundations, presses, automatic
shearing machines, occlusion machines,
compressors, fans, air conditioners, etc
Performance:
.jpg)

➤Low-frequency active or passive damping
➤The vertical and horizontal stiffness is
about 1:1
➤ Vibration isolation
➤ Impact absorption
➤Structural soundproofing
➤ No anchoring is required
➤ It can be operated without inflation
➤Load range: 0.2 – 100 kN
➤ Natural frequency (static) 3 – 5 Hz
➤Natural frequency (static) is not inflated at 8 Hz
.jpg)

Materials
➤ High-elasticity neoprene main body, oil-resistant and aging-resistant
➤ Load plate and base plate:
- SLM 1 ‒ 12: aluminum plate
- SLM 24 ‒ 192: galvanized steel plate
➤ Grade 8.8 galvanized bolts
Leveling range: leveling range ± 5 - 6 mm, air pressure control
Optional Accessories
Automatic Leveling Control:
➤ Mechanical-Pneumatic Version
➤ Electric-Pneumatic Version
(Can set reset time and accuracy)
Automatic pressure monitoring reduces maintenance: works with SLM H90 IC control system
Scope of Delivery: Air spring with hex head bolts
Accessories: Mounting Plate
When the area at the bottom of the machine is small, the mounting plate distributes the load evenly across the entire component area
➤ High-elasticity neoprene main body, oil-resistant and aging-resistant
➤ Load plate and base plate:
- SLM 1 ‒ 12: aluminum plate
- SLM 24 ‒ 192: galvanized steel plate
➤ Grade 8.8 galvanized bolts
Leveling range: leveling range ± 5 - 6 mm, air pressure control
Optional Accessories
Automatic Leveling Control:
➤ Mechanical-Pneumatic Version
➤ Electric-Pneumatic Version
(Can set reset time and accuracy)
Automatic pressure monitoring reduces maintenance: works with SLM H90 IC control system
Scope of Delivery: Air spring with hex head bolts
Accessories: Mounting Plate
When the area at the bottom of the machine is small, the mounting plate distributes the load evenly across the entire component area


| SLM Series |
Diameter D |
Installation
height
H0 |
Base size D1 |
The support
surface
fixes the
size of the
threaded
hole
G |
Overall length L |
Machine
base
thickness
(max.) |
Lifting
range
of
height
Ni |
Height
of
support
surface X |
Width
of base
plate
A |
Base hole
spacing b |
Base
fixing hole
size
d |
Base plate
thickness
T |
Weiight |
Maximum
load
|
| SLM 1 A | 73 | 65 | 28 | M10 | 80 | 50 | ±5 | 12 | 75 | 60 | 7 | 3 | 0.3 | 0.65 |
| SLM 3 A | 105 | 65 | 52 | M12 | 90 | 65 | ±5 | 12 | 105 | 89 | 7 | 3 | 0.5 | 1.8 |
| SLM 6 A | 127 | 90 | 60 | M12 | 90 | 65 | ±6 | 15 | 130 | 108 | 7 | 3 | 1 | 2.8 |
| SLM 12 B | 172 | 90 | 96 | M12 | 90 | 65 | ±6 | 15 | 175 | 153 | 7 | 3 | 2.2 | 6 |
| SLM 24 A | 245 | 90 | 138 | M16 | 100 | 75 | ±6 | 15 | 255 | 215 | 14 | 5 | 7.2 | 13 |
| SLM 48 A | 338 | 90 | 205 | M16 | 100 | 75 | ±6 | 15 | 343 | 305 | 14 | 5 | 14.7 | 26 |
| SLM 72 A | 380 | 91 | 255 | M24 x 1.5 | 140 | 75 | ±6 | 17 | 385 | 310 | 20 | 6 | 22.5 | 38 |
| SLM 96 A | 468 | 90 | 300 | M24 | 130 | 75 | ±6 | 15 | 470 | 406 | 20 | 6 | 29.3 | 55 |
| SLM 144 A | 550 | 91 | 360 | M24 x 1.5 | 140 | 75 | ±6 | 17 | 555 | 480 | 20 | 6 | 46.5 | 76 |
| SLM 192 A | 610 | 90 | 430 | M24 | 130 | 75 | ±6 | 15 | 610 | 508 | 20 | 6 | 52.5 | 100 |
Unit: mm