SLM-IC Air Spring Isolator
The SLM-B IC system uses the same controller as the ADS
series, providing automatic pressure monitoring and
additional control parameters.
➤ Natural frequency: 3 ‒ 5 Hz
➤ SLM-IC structure
➤ Rubber-metal combination base plate fixed with bolts.
➤ Natural frequency: 3 ‒ 5 Hz
➤ SLM-IC structure
➤ Rubber-metal combination base plate fixed with bolts.
System Functions
The air spring comes with factory default settings. At the same time, the following parameters can be changed through the control software: reset accuracy, allowable deformation, response time, and average height. These parameters can be viewed, adjusted, and permanently stored in each spring. Even after a power outage, these values are retained. The control software can be used to restore the default settings.
The air spring comes with factory default settings. At the same time, the following parameters can be changed through the control software: reset accuracy, allowable deformation, response time, and average height. These parameters can be viewed, adjusted, and permanently stored in each spring. Even after a power outage, these values are retained. The control software can be used to restore the default settings.
IC Air Spring System Composition:
➤4 supporting points
- 3 pneumatic springs SLM type Master with
sensors and control valves
- 1 pneumatic spring SLM type Slave without
sensors and valves
➤1 control unit, 3-channel circuit board with USB interface
➤ Communication cable for the main control spring
➤Pressure Regulating Valve (NW 4 Module)
➤Power adapter
Supply Requirements
➤ Compressed Air:
- Operating pressure 1 ‒ 6 bar, dry, dust-free, oil-free
- Optional filter regulator (FRK)
➤ Control Module:
- Circuit board dimensions: 160 x 100 x 15 mm
- Control module housing dimensions: 225 x 200 x 40 mm
➤ Power Supply:
- DC power: 24 V ‒ 1A
- AC power adapter: 230 V, 50 Hz, 130 W, output 24 V, 1A, DC
➤ PC Interface: USB to RS-232
➤ Air Level Control software
Supply Requirements
➤ Compressed Air:
- Operating pressure 1 ‒ 6 bar, dry, dust-free, oil-free
- Optional filter regulator (FRK)
➤ Control Module:
- Circuit board dimensions: 160 x 100 x 15 mm
- Control module housing dimensions: 225 x 200 x 40 mm
➤ Power Supply:
- DC power: 24 V ‒ 1A
- AC power adapter: 230 V, 50 Hz, 130 W, output 24 V, 1A, DC
➤ PC Interface: USB to RS-232
➤ Air Level Control software

|
SLM-IC series
|
D | H0 | Ni | A | Maximun load kN |
| SLM-IC-3 | 105 | 65 | ± 5 | 106 | 1.8 |
| SLM-IC-6 | 127 | 90 | ± 6 | 130 | 2.8 |
| SLM-IC-12 | 175 | 90 | ± 6 | 175 | 6 |
| SLM-IC-12 B | 170 | 90 | ± 6 | 175 | 6 |
| SLM-IC-24 | 245 | 90 | ± 6 | 255 | 13 |
| SLM-IC-48 | 338 | 90 | ± 6 | 343 | 26 |
| SLM-IC-96 | 468 | 90 | ± 6 | 470 | 55 |
| SLM-IC-192 | 610 | 90 | ± 6 | 610 | 100 |
Unit=mm